Sanitary Sensor
HOME > Products Index > Sanitary Sensor > VHST(Terminal box type)

Sanitary SensorSanitary Pressure Transmitter

VHSTseries Terminal box type

50kPa~3000kPa
VNS/VHS Terminal box Model T

Output 4-20mA (2 wire system) scaling function. (Supports negative pressure, compound pressure and reverse output.)
IP67 construction for environmental construction.
Safe and reliable construction with break-proof diaphragm.
Safe and reliable construction with no sealed liquid.

Standard feature
●Damping ●Loop check function ●FIX zero
●Quick zero-adjustment ●Maximum/Minimum display
●Various functions such as output burnout at error.

Measured medium Liquor, milk beverage, seasoning, pure water, chemical or other media.
(These vary according to sensor materials)
Pressure type Positive, compound, and negative pressures can be measured.
Pressure range Can be specified within the range of 50 kPa to 3 MPa of rated capacity.
Output type 4~20mA (2 wire system) Output scaling variable.
Output scaling can be changed within the range of 10 to 100% of the rated capacity.

Specification 1 (Sensor assembly)

Pressure Port Type/Size ISO Ferrule, VARIVENT®, ISO Cap nut, Other special orders
Rated Capacity(R.C.) 50kPa~3MPa
Material Sensor: SUS316L / Hastelloy C276 / SUS329J4L
Finish(Sensor Part) Electro-Chemical Buffing
Safe Overload Rating 400%R.C.(Rated capacity 3MPa: 150%R.C.)
Destruction Point 1000%R.C.(Rated capacity 3MPa: 300%R.C.)

Specification 2 (Amplifier + Sensor assembly)

Normal Temperature Accuracy(*1)
(Non Linearity, hysteresis and repeatability included.)
20~100%R.C. Scaling
Positive pressure side :
±0.5% F.S. or less(Negative pressure side : ±1% F.S. or less)
10~20%R.C. Scaling
Positive pressure side·Negative pressure side :
±1% F.S. or less
Compensated Temperature Range -5~150°C(Temperature of medium to be measured)
Safe Temperature Range -5~150°C(Temperature of medium to be measured)
Temperature Effect on Zero Balance ±0.5%R.C./10°C or less
Temperature Effect on Load ±0.5%R.C./10°C or less
Ambient Temperature and Humidity Temperature:0~50°C(Amplifier/Display part)
Humidity:0~90%RH(No condensation)
Material Aluminum die casting(Case material), SUS304(Radiating fin)
IP Rating Equivalent to IP67
Mass Approx. 1100g
(A sensor assembly is included. / In the case of ISO ferrule 2S)
Accessories Operation manual (1 copy), Test report (1 copy),
Cable gland, Waterproofing protective plug for exhaust
  • (*1) For the ferrule type, zero adjustment is to be made after the clamp is tightened.

Model Selection

Model Selection
Selection Check Model Specification
1.Model VHST High temperature type: Temperature range of wetted parts -5~150°C
2.Display/Output A6V 4~20mA(2 wire system) Output scaling variable
Responsive: Damping (Soft filter) Default 2 seconds (0.5Hz)
3.Calibration   Pressurization & Negative pressure ⑤Specify the rated capacity and unit.
*In case of negative pressure, put the calibration range value in parentheses.
  Compound pressure Compound pressure(Calibration range with plus/minus sign)(*2)
4.Rated Capacity(R.C.)   005 50kPa Calibration range specification [50.0kPa]
  010 100kPa Calibration range specification [100.0kPa]
  020 200kPa Calibration range specification [200kPa] Compound[(-100~200)kPa](*2)
  021 200kPa Calibration range specification [(-100~200)kPa](*2)
(Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)
  030 300kPa Calibration range specification [300kPa] Compound[(-100~300)kPa](*2)
  031 300kPa Calibration range specification [(-100~300)kPa](*2)
(Specify this model at calibration for compound pressure if "focus on negative pressure" has been selected.)
  050 500kPa Calibration range specification [500kPa]
  100 1000kPa Calibration range specification [1000kPa]
  300 3MPa [Display/Calibration: Specify 3.00MPa]3MPa Calibration range specification [3.00MPa][Make to order]
(Withstand pressure:150%R.C.
ISO Cap nut and Screw mount only)
5.Pressure Port Type/Size   F1 ISO Ferrule 1.5S
  F2 ISO Ferrule 2S
  F3 ISO Ferrule 2.5S[Make to order]
  F4 ISO Ferrule 3S[Make to order]
  F6 ISO Ferrule 4S[Make to order]
  V50A VARIVENT® DN50[Make to order]
  V65A VARIVENT® DN65[Make to order]
  V80A VARIVENT® DN80[Make to order]
  V100A VARIVENT® DN100[Make to order]
  R1 ISO Cap nut 1.5S[Make to order] Hexagon nut included (HEX61)
  R2 ISO Cap nut 2S[Make to order] Hexagon nut included (HEX76)
  M0 Screw mount type simple substance Dedicated O-ring included (×1)
  M1 JIS20K50A With flange, Dedicated O-ring included (×1)
  M2 JIS20K80A With flange, Dedicated O-ring included (×1)
6.Pressure Port Material   Blank SUS316L, Electro-Chemical Buffing(Rz0.7)
④Supports all rated capacities.
⑤Supports all pressure port type/size.
  HS1 Hastelloy C276, Electro-Chemical Buffing(Rz0.7)
④Rated capacitor can be selected from among 300, 500 and 1000kPa.
⑤Pressure port type/size can be selected from among F1, F2, F3 and M0.
[Make to order]
Negative pressure and compound pressure are not supported
  J4L SUS329J4L, Buffing(#400)
④Rated capacitor can be selected from among 300, 500 and 1000kPa.
⑤Pressure port type/size can be selected from among F1, F2, F3 and M0.
7.Limitation   H 400%R.C.(3MPa is not selectable)
  Blank 150%R.C.(3MPa only)
8.Power 4 DC24V (DC8.82~26.5V) Consumption current: Approx. 23mA
  • (*2) In case of calibration for compound pressure, calibration is performed only for the positive pressure, and only measurement data are given for the negative pressure. In this case, acceptance criterion is within ±1%R.C. When focusing on the negative pressure, it is also possible to perform calibration for the negative pressure and to provide only measurement data (within ±1%R.C.) according to the request from the customer.
    Regarding calibration, specify 020, 030 (focus on positive pressure) or 021, 031 (focus on negative pressure) in ④ above when placing an order.
  • (*3) Output range is factory-adjusted to the specified rate in the range 10 to 100%, with the calibration range set at 100%. (Option)
    <Example> When using a rated capacity of 100kPa and outputting analog signal of 4 to 20mA for the pressure of 0 to 70kPa, specify VSHT-SC1: Differential pressure 0~70kPa.

Learn more about external dimensions.


.