Pressure Transmitter

Pressure TransmitterHigh Vacuum Pressure Transmitter

VCCP series

VSST(SF/RR/WT/WF)
 *Available digital panel meters
   >>Click here for the list.

Measurement of the high vacuum area is possible.
0~1500Pa(abs), 0~5kPa(abs) and 0~10kPa(abs)
High leak performance
Maximum allowable pressure (400kPa)

Measured medium Water, oil, gases or other media that will not corrode Ceramic + SUS316L + O-ring.
Pressure type Compound pressure can be measured.
Measured Range Can be specified within the range of 1500Pa(abs), 5kPa(abs) and 10kPa(abs) of calibration.
Output type Specify among 2 to 20mA(4 wire system), 1 to 5V

Specification

Non Linearity ±0.8%F.S. or less
Hysteresis ±0.8%F.S. or less
Range of Use Temperature 0~70°C (No condensation or freezing)
Temperature Effect on Load ±0.5%F.S. / ±10°C or less
Safe Overload Rating ±0.5%F.S. / ±10°C or less
Connection Screw Material SUS316L
Sensor Element Alumina ceramic
O-ring Material Selected from EPDM or Fluororubber (Class 4D) or Perfluoro-Elastomer
Case Material SUS304
IP Rating Equivalent to IP54
Power DC24V (±10%)
Mass Approx. 470g
Accessories Operation manual (1 copy), Test report (1 copy)

Model Selection

Model Selection
Selection Check Model Specification
1.Model VCCP High Vacuum Pressure Transmitter
2.Output - - Output type Response frequency Safe load resistance Consumption current
  A2 1~5V 250Hz 5kΩ or more Approx. 25mA
  A3 4~20mA(4 wire system) 250Hz DV24V 500Ω or more Approx. 42mA
3.Calibration - - Rated capacity Example of calibration range
  See right table. Enter the range in the   as it is. 1500Pa(abs) 1500Pa(abs) (0~1500Pa(abs))
5kPa(abs) 5kPa(abs) (0~5kPa(abs))
10kPa(abs) 10kPa(abs) (0~10kPa(abs))
4.Cable Connection   WN Connecting cable None
  WS Waterproof connector (Straight type) + Cable 2m
  WR Waterproof connector (Angle type) + Cable 2m
5.Rated Capacity   C10KPA 10kPa (abs)
6.Connection   R2 Connection thread: R1/4
  R3 Connection thread: R3/8
  G2 Connection thread: G1/4 , O-ring to be used by the selection of ⑧
  G3 Connection thread: G3/8 , O-ring to be used by the selection of ⑧
7.Pressure Port Material S SUS316L (Case: SUS304)
8.O-ring Material   E EPDM
  F Fluororubber (Class 4D)
  P Perfluoro-Elastomer
9.Power 4 DC24V (±10%)

Learn more about external dimensions.


.