Specialized manufacturer of Digital Pressure Meters and Load Cells

VALCOM CO.,LTD.

Made-to-order

High Load-resistant Single Point type Load Cell
VPW18C3/H1 series
5kg–75kg

  • Extremely high overload limit (Fracture load: 1000%, mechanical stopper included)
  • Good environmental resistance
  • Highly resistant against lateral load and bending stress

Specifications

Rated output 0.900–1.100mV/V
Nonlinearity ±0.0166%R.C.
Hysteresis ±0.0166%R.C.
Zero balance −0.200–0.200mV/V
Temperature effect on zero balance ±0.0140%R.C./10°C
Temperature effect on load 20–40°C:±0.0175%R.C./10°C
-10–20°C:±0.0117%R.C./10°C
Safe overload rating 800%R.C.
Temperature compensation range −10–40°C (No condensation or freezing)
Safe temperature range −10–50°C (No condensation or freezing)
Input terminal resistance 350.0–500.0Ω
Output terminal resistance 350.0–500.0Ω
Recommended excitation voltage 5V
Excitation voltage range 1–12V
Insulation resistance 1000MΩ (DC100V)
IP rating Equivalent to IP66 (Note 1)
Cable 6-core cable 3m
  • Creep 30min: ±0.0166%R.C.
  • (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.

Model selection

Selection Model Rated capacity Maximum Load Area Ultimate overload rating Deflection at R.C. Weight
  VPW18C3/H1-5kg 5kg (49.03N) 400×400mm 1000%R.C. Approx. 0.15mm Approx. 3kg
  VPW18C3/H1-10kg 10kg (98.07N)
  VPW18C3/H1-20kg 20kg (196.1N)
  VPW18C3/H1-50kg 50kg (490.3N) 600×500mm
  VPW18C3/H1-75kg 75kg (735.5N)
  • *Weight includes cable.

External dimensions (Unit: mm)

External dimensions