Specialized manufacturer of Digital Pressure Meters and Load Cells

VALCOM CO.,LTD.

Made-to-order

Lightweight Flat type Load Cell (R.C. 5MN)
VC6A-5MN
5MN

  • Compact and lightweight Approx. 33kg
  • Good environmental resistance
  • Can measure up to 5MN

Specifications

Rated output 1.990–2.010mV/V (With a spherical support) (*1)
Nonlinearity ±0.5%R.C.
Hysteresis ±0.8%R.C.
Zero balance −0.10–0.10mV/V
Temperature effect on zero balance ±0.05%R.C./10°C
Temperature effect on load ±0.1%R.C./10°C
Safe overload rating 150%R.C.
Relative Static Lateral Limit Force With a pressure-proof hard plate: 20%,
With a load button or a bendall bearing: 10%,
With a spherical support: 10%
Permissible Vibration Amplitude to DIN 50100 70%
Temperature compensation range −10–70°C (No condensation or freezing)
Safe temperature range −30–85°C (No condensation or freezing)
Input terminal resistance 345.0–500.0Ω
Output terminal resistance 354.5–357.5Ω
Recommended excitation voltage 5V or less
Excitation voltage range 0.5–12V
Insulation resistance 5000MΩ (DC100V)
IP rating Equivalent to IP65 (Note 1)
Cable φ6.5mm with Shielded 6m, directly-connected
  • (*1) With a load button or a bendall bearing: 1.990–2.010mV/V With a pressure-proof plate: 1.980–2.020mV/V
  • Creep 30min (Within temperature compensation range): ±0.06%R.C.
  • (Note 1) Sealing performance of the cable outlet may deteriorate due to the change of cable jacket over years.

Model selection

Selection Model Rated capacity Deflection at R.C. Weight
  VC6A-5MN 5MN Approx. 0.26mm Approx. 33kg
  • *Weight includes cable.

External dimensions (Unit: mm)

External dimensions

Membership is required to use the download service.
If you have already finished registration, log in from here.

■ E-mail address
■ Password