Specialized manufacturer of Digital Pressure Meters and Load Cells

VALCOM CO.,LTD.

 

Round Digital Pressure Meter with Analog/BCD Output
VPC series
(Sensor direct connection type, with analog/BCD output)
50kPa–100MPa
50kPa abs–1700kPa abs


* Actual products may differ from photo depending on specifications.

  • 5 analog outputs and 3 BCD outputs can be selected and used together.
  • Fast response analog output without microcomputer is available that is suitable to fluid pressure measurement.
  • High accuracy and long life.
  • Can be selected from abundant pressure range.
Measured medium Air, gases, water, oil or other media.
(Depends on the material of sensor.)
Pressure type Positive, negative, compound and absolute pressures can be measured.
Pressure range Pressure sensor series ranging from low pressure, absolute pressure, and medium-to-high pressure up to 100 MPa are available.
(See photos on the left for pressure sensors.)

Specifications

Display 1999 3 ½digit Super luminosity Red LED (Character height: Approx. 15mm)
Display Conversion Speed 3times/sec. (Standard), Can be set in the range of 1–15 times/s.
Accuracy (*1) ±0.05%F.S.±1digit
Use Temperature Range 0–55°C (No freezing)
Use Humidity Range 0–90%RH (No condensation)
External dimensions φ104×56 (D:Protrusions not included)
Weight Approx. 650g (Varies with specification)
Accessories Operating manual 1 copy (Specify English or Japanese.)
Test report 1 copy(*2)
  • (*1) Take into account the accuracy of the pressure sensor selected from the table.
  • (*2) For accessories such as connectors, refer to the pages of Accessories and Options.

Model Selection

Example

Selection of Pressure sensor

Refer to Selection Table for Pressure Sensors for specification and model numbers and specify the desired model.
[e.g.] VPC - A3B1 - S - A - 1.000MPa - 1 / VPRQ - 1MP

Selection of Power converter

Only when AC power is used, refer to the Power Converters page, and specify the model.
[e.g.] TUC - AC100V - 3 - 1N
Selection Check Model Specifications
1.Model VPC Round Digital Pressure Meter with Analog/BCD Output
2.output - - Output type Response frequency Safe load resistance
  Blank None
  D Display only (No output)
*When D is selected, analog output and BCD output are not available.
- -
  A1 1mV/digit (±1999mV max.) 1.2kHz This value has been calculated as response frequency (= 1/2T (Hz)) based on the measured step response (0–100%) and rise time (T) with the sensor bridge resistance of 350Ω.
Response frequency is determined by the sensor to be used. Consult with us when focusing on response.
10kΩ or more
  A2 1–5V
  A3 4–20mA (4-wire) 333Hz 250Ω or less
  A4 0–5V 1.2kHz 10kΩ or more
  A5 0–10V
3.BCD Output - - Output type Response frequency Safe load resistance
  Blank None - -
  B1 BCD TTL (Positive) Synchronized with the display conversion rate. ±3mA
  B2 Discontinued
BCD TTL (Negative)
  B1O BCD Open collector
(Signal output Tr OFF)
35V 25mA
  B2O BCD Open collector
(Signal output Tr ON)
4.Panel Mounting Parts   S Without panel bracket: A=Fixed at S for the models with sensor directly connected on bottom.
  P With panel bracket: B=Available only for the models with sensor directly connected on bottom.
5.Casing type   A Directly connected on bottom side (Pressure sensor only)
  B Directly connected on back side (Pressure sensor only)
6.Display/Calibration     Specify the range within the rated capacity of the applicable pressure sensor.(Within 50% of the rated capacity)
*Refer to Selection Table for Pressure Sensors for the rated capacity.
7.Power [Power Consumption]   1 AC100V [5VA] When specifying AC power, a dedicated power converter "TUC" will be included. Click here for the specifications of power converters.
  11 AC110V [5VA]
  2 AC200V [5VA]
  22 AC220V [5VA]
  3 DC±12V [200mA]
  4 DC24V [100mA]
  5 DC12V [200mA] *Not available when analog output is A5
8.Indication Conversion Rate
(Option)
    Indication Conversion Rate 3 times/sec. Option ( times/sec.)
*Specify in the range of 1–15 times/s.

External dimensions (Unit: mm)

External dimensions
Selection table for pressure sensor
Pressure sensor Discontinued
VPMR
Discontinued
VPMG
VHR3 VHG3 VAR3 VAG3 VPNPR VPNPG
Connection screw R3/8 G3/8 R3/8 G3/8 R3/8 G3/8 R3/8 G3/8
Rated capacity 5–350kPa 50kPa
(or kPa abs)
100–700kPa
(or kPa abs)
100–1700kPa
(or kPa abs)
Drawing
Pressure sensor VNF VPRF VPRT VPRTF
Connection screw G3/4 G3/8 R3/8 G3/8
Rated capacity 100–1700kPa (or kPa abs) 1–50MPa 1–50MPa
Drawing
Pressure sensor VPRT VPRTF VPRQ VPRQF VPRQF
Connection screw R1/2 G1/2 R3/8 G3/8 G1/2
Rated capacity 100MPa 1–50MPa 100MPa
Drawing

1–35MPa

50MPa

100MPa

Output specification

Output specification

Power specification

Power specification

*Only when AC power is used, select exclusive trans unit. (Refer to the "Exclusive power for VPC" page.)

Membership is required to use the download service.
If you have already finished registration, log in from here.

■ E-mail address
■ Password